Hi all
Here’s my setup: (10) VSun 400w panels (VSUN400-108BMH) (10) Enphase IQ8+ micro inverters (IQ8PLUS-72-2-US) (1) Enphase Q Cable (Q-12-10-240) (1) Enphase combiner/gateway (X2-IQ-AM1-240-4)
Originally I was planning on having them in a single row but ended up having to group them differently on the roof.
Now I have: 1 row of 4 portrait 1 row of 4 portrait 1 single landscape 1 single landscape
I used MC4 connectors as couplings between the groups of panels noted above.
In Enlighten Toolkit I have the system set up as a single row of 10 portrait in the array.
I have the PV line going into the Combiner into a 40A breaker in slots 1/3.
From the lugs on the Combiner I am going to the solar side of a Siemens solar ready meter main. Currently using a 30A breaker I had on hand.
When I power on the solar side of the meter main and the 2 breakers in the Combiner (PV and the gateway), it takes a minute to boot up.
In Enphase Toolkit: I see all 10 IQ8 micro inverters. All 10 have the 4 green dots lit up. All 10 report: —- AC Voltage Out of Range: Phase 1 —- AC Frequency out of range
Across the lugs at the Combiner I have 246V and 123V on the each leg to ground.
Utility is Southern California Edison (SCE).
Left the system up over 3 days to see if those errors would self regulate but still the same this morning.
Any advice/suggestions on what I can do to troubleshoot this system?
Thanks!
submitted by /u/zebracat
[link] [comments]